Dissolved oxygen sensors are an essential component in monitoring the quality of water bodies, including lakes, rivers, and oceans. These sensors measure the amount of oxygen dissolved in the water, which is a critical factor in determining the health of aquatic ecosystems. The purpose of a dissolved oxygen sensor is to provide real-time data on the concentration of oxygen in the water, which can be used to assess the health of aquatic life and identify potential issues related to pollution or other environmental factors. In this article, we will explore the role of dissolved oxygen sensors in water quality monitoring and how they help to protect our precious water resources.

Quick Answer:
The purpose of a dissolved oxygen sensor is to measure the concentration of oxygen in a liquid or gas. This type of sensor is commonly used in aquariums, wastewater treatment plants, and other applications where monitoring oxygen levels is important. The sensor works by measuring the amount of oxygen that is dissolved in the liquid or gas, and then converting this measurement into a readable output, such as a digital readout or an analog signal. Dissolved oxygen sensors are an important tool for monitoring the health of aquatic ecosystems, as well as for ensuring that industrial processes are operating efficiently and safely.

How Dissolved Oxygen Sensors Work

The Science Behind Dissolved Oxygen Measurement

Dissolved oxygen sensors measure the amount of oxygen present in a liquid, such as water or blood. The measurement is made by detecting the amount of oxygen that is dissolved in the liquid. The amount of oxygen present in a liquid is important for many applications, including environmental monitoring, industrial processes, and medical diagnosis.

Dissolved oxygen sensors work by measuring the amount of oxygen present in a liquid using electrochemical sensors. These sensors are based on the principle that oxygen can be reduced at an electrode to form water. The current generated by this reaction is measured and used to determine the amount of oxygen present in the liquid.

There are two main types of dissolved oxygen sensors: polarographic and galvanic. Polarographic sensors use a platinum electrode to measure the current generated by the reduction of oxygen. Galvanic sensors use two electrodes, one of which is a reference electrode, to measure the potential difference between the two electrodes.

Both types of sensors have their advantages and disadvantages. Polarographic sensors are more accurate and have a wider range of measurement, but they are also more expensive and require more maintenance. Galvanic sensors are less expensive and require less maintenance, but they have a narrower range of measurement and may be less accurate.

Overall, dissolved oxygen sensors play an important role in many fields and are used to measure the amount of oxygen present in a liquid. These sensors use electrochemical principles to generate a current that is proportional to the amount of oxygen present in the liquid, and this current is then measured to determine the concentration of oxygen.

Components of a Dissolved Oxygen Sensor

A dissolved oxygen sensor is a device that measures the concentration of oxygen in a liquid. It is commonly used in various applications, such as in water treatment plants, aquariums, and bioreactors. The purpose of a dissolved oxygen sensor is to monitor the amount of oxygen present in a liquid and ensure that it remains within a specific range.

The components of a dissolved oxygen sensor include:

  1. Oxygen-sensitive element: This is the heart of the sensor and is typically made of a metal oxide semiconductor material. The oxygen-sensitive element is designed to produce a signal that is proportional to the concentration of oxygen in the liquid.
  2. Reference electrode: This is an electrode that provides a stable reference potential for the sensor. The reference electrode is typically made of a material that is stable in the liquid being measured.
  3. Signal electrode: This is an electrode that is used to measure the concentration of oxygen in the liquid. The signal electrode is typically made of a material that is sensitive to changes in the concentration of oxygen.
  4. Amplifier: This is a device that amplifies the signal produced by the oxygen-sensitive element. The amplifier is typically designed to provide a linear output that is proportional to the concentration of oxygen in the liquid.
  5. Output stage: This is the final stage of the sensor and is responsible for converting the amplified signal into a measurable output. The output stage may include a digital or analog display, or it may provide an output signal that can be read by a computer or other data-logging device.

Overall, the components of a dissolved oxygen sensor work together to provide a reliable and accurate measurement of the concentration of oxygen in a liquid. This measurement is critical for many applications, as oxygen is essential for the proper functioning of biological systems and can have a significant impact on the quality of water and other liquids.

Applications of Dissolved Oxygen Sensors

Key takeaway: Dissolved oxygen sensors play a crucial role in monitoring water quality, industrial process control, and medical applications. These sensors use electrochemical principles to measure the concentration of oxygen in a liquid, which is important for many applications, including environmental monitoring, industrial processes, and medical diagnosis. However, challenges such as interference from other gases and temperature effects can impact the accuracy of dissolved oxygen sensors. To mitigate these challenges, proper calibration and maintenance procedures are crucial. Future developments in dissolved oxygen sensor technology include miniaturization and portability, as well as integration with IoT and AI systems.

Monitoring Water Quality

Dissolved oxygen sensors play a crucial role in monitoring water quality in various bodies of water, including lakes, rivers, and oceans. These sensors are designed to measure the concentration of dissolved oxygen in the water, which is essential for sustaining aquatic life. Here are some key points to consider:

Importance of Dissolved Oxygen in Water

Dissolved oxygen (DO) is a measure of the amount of oxygen present in water, which is necessary for the survival of aquatic organisms. The concentration of dissolved oxygen in water can vary depending on various factors, such as temperature, salinity, and the presence of other chemicals.

Monitoring Water Quality

Dissolved oxygen sensors are used to monitor the concentration of dissolved oxygen in water, which is essential for determining the overall quality of the water. These sensors can help identify areas with low dissolved oxygen levels, which can be caused by factors such as pollution, overfishing, or changes in temperature and climate.

Benefits of Monitoring Water Quality

Monitoring water quality is essential for ensuring the health of aquatic ecosystems and the organisms that inhabit them. By using dissolved oxygen sensors, it is possible to identify areas where the concentration of dissolved oxygen is too low, which can be an indication of poor water quality. This information can be used to take corrective action, such as reducing pollution or implementing regulations to protect the environment.

Challenges in Monitoring Water Quality

One of the main challenges in monitoring water quality is the variability of dissolved oxygen levels in different areas. This can be due to factors such as the presence of aquatic plants, the movement of water, and changes in temperature and salinity. Therefore, it is important to use high-quality sensors and to calibrate them regularly to ensure accurate measurements.

In conclusion, dissolved oxygen sensors play a critical role in monitoring water quality in various bodies of water. By measuring the concentration of dissolved oxygen, it is possible to identify areas with low dissolved oxygen levels, which can be an indication of poor water quality. This information can be used to take corrective action and protect the health of aquatic ecosystems and the organisms that inhabit them.

Industrial Process Control

Dissolved oxygen sensors play a crucial role in industrial process control, enabling operators to monitor and control the level of dissolved oxygen in various industrial processes. The main purpose of dissolved oxygen sensors in industrial process control is to ensure that the oxygen concentration in the process remains within a specified range for optimal performance and to prevent the growth of microorganisms that can cause corrosion, fouling, or biological growth.

Here are some key points about the use of dissolved oxygen sensors in industrial process control:

Monitoring Oxygen Levels in Wastewater Treatment

In wastewater treatment plants, dissolved oxygen sensors are used to monitor the levels of dissolved oxygen in the wastewater to ensure that the oxygen levels are sufficient to support the biological process of breaking down organic matter. If the oxygen levels fall below a certain threshold, it can indicate a problem with the treatment process, such as a lack of aeration or inadequate mixing. Operators can then take corrective action to maintain the optimal oxygen levels and ensure that the wastewater is properly treated before it is discharged into the environment.

Controlling Oxygen Levels in Bioreactors

Bioreactors are used in various industrial processes, such as the production of chemicals, food, and pharmaceuticals, to grow microorganisms. Dissolved oxygen sensors are used to monitor the oxygen levels in the bioreactor to ensure that the microorganisms are receiving sufficient oxygen for growth. If the oxygen levels fall below a certain threshold, it can indicate a problem with the aeration system or other process parameters, and operators can take corrective action to maintain the optimal oxygen levels for efficient and safe operation.

Monitoring Oxygen Levels in Power Generation

In power generation, dissolved oxygen sensors are used to monitor the oxygen levels in cooling water systems to ensure that the oxygen levels do not fall below a certain threshold, which can cause corrosion and fouling of the cooling system. By monitoring the oxygen levels, operators can take corrective action to maintain the optimal oxygen levels and prevent damage to the cooling system, which can extend the life of the equipment and reduce maintenance costs.

Optimizing Oxygen Transfer in Aeration Systems

In aeration systems used for industrial processes, dissolved oxygen sensors are used to monitor the oxygen levels to ensure that the oxygen transfer is efficient and effective. By monitoring the oxygen levels, operators can adjust the aeration parameters, such as the flow rate and pressure, to optimize the oxygen transfer and ensure that the oxygen levels in the process remain within the specified range. This can improve the overall efficiency of the process and reduce energy consumption.

Overall, dissolved oxygen sensors play a critical role in industrial process control by enabling operators to monitor and control the level of dissolved oxygen in various industrial processes. By ensuring that the oxygen levels remain within the specified range, operators can prevent problems with corrosion, fouling, and biological growth, and optimize the performance of the process, resulting in improved efficiency, reduced costs, and minimal environmental impact.

Medical Applications

Dissolved oxygen sensors have numerous applications in the medical field. They are used to measure the amount of oxygen present in a patient’s blood or other bodily fluids. The purpose of measuring dissolved oxygen is to assess the efficiency of the body’s oxygen transport system and to monitor the effectiveness of treatments.

One of the main applications of dissolved oxygen sensors in medicine is in the treatment of respiratory disorders. The sensor is used to monitor the oxygen levels in the lungs of patients with conditions such as chronic obstructive pulmonary disease (COPD) and asthma. This helps doctors to determine the appropriate treatment and to adjust the dosage of medication to ensure that the patient is receiving enough oxygen.

Another application of dissolved oxygen sensors in medicine is in the monitoring of anesthesia during surgery. The sensor is used to measure the oxygen levels in the blood of patients under anesthesia. This helps to ensure that the patient is receiving enough oxygen and that the anesthesia is working effectively.

In addition, dissolved oxygen sensors are used in the treatment of wounds and burns. The sensor is used to measure the oxygen levels in the wound or burn bed. This helps to ensure that the wound or burn is receiving enough oxygen to heal properly.

Overall, dissolved oxygen sensors play a crucial role in the medical field by providing a means of monitoring oxygen levels in the body. This helps doctors to assess the effectiveness of treatments and to adjust them as necessary to ensure that the patient is receiving the appropriate level of oxygen.

Benefits of Using Dissolved Oxygen Sensors

Accurate and Reliable Measurement

Dissolved oxygen sensors offer several advantages over traditional measurement methods, including the ability to provide accurate and reliable measurements. Here are some of the key benefits of using dissolved oxygen sensors for measuring oxygen levels in water:

High Precision

Dissolved oxygen sensors are designed to provide highly accurate measurements, with a high degree of precision. They use a range of different technologies to measure the concentration of oxygen in water, including optical sensors, electrochemical sensors, and others. These sensors are designed to provide precise measurements, even in challenging environments where other measurement methods may be less reliable.

Real-Time Monitoring

Another key advantage of dissolved oxygen sensors is their ability to provide real-time monitoring of oxygen levels in water. This is particularly important in applications such as wastewater treatment, where rapid changes in oxygen levels can have significant implications for the treatment process. By providing real-time data, dissolved oxygen sensors can help operators to respond quickly to changes in oxygen levels, and make adjustments to the treatment process as needed.

Non-Destructive Measurement

Unlike some other measurement methods, dissolved oxygen sensors are non-destructive, meaning they do not alter the water being measured. This is particularly important in applications such as environmental monitoring, where it is important to minimize any potential impact on the ecosystem being studied. By providing non-destructive measurements, dissolved oxygen sensors can help to ensure that the integrity of the water being measured is preserved.

Cost-Effective

Finally, dissolved oxygen sensors are often more cost-effective than traditional measurement methods. This is because they can provide accurate measurements with less equipment and fewer resources, making them a cost-effective solution for a wide range of applications. Additionally, because they provide real-time data, dissolved oxygen sensors can help to reduce costs associated with labor-intensive data collection and analysis.

Real-Time Monitoring

Dissolved oxygen sensors provide real-time monitoring of the concentration of dissolved oxygen in water. This feature is of great benefit to various industries, such as agriculture, aquaculture, and wastewater treatment, as it allows for timely detection of any changes in the oxygen levels. Real-time monitoring enables quick action to be taken in response to changes in dissolved oxygen levels, ensuring that optimal conditions are maintained for the processes being monitored.

Cost-Effective Solutions

One of the primary advantages of using dissolved oxygen sensors is their cost-effectiveness. Compared to traditional methods of measuring dissolved oxygen levels, such as using laboratory equipment or manually testing samples, dissolved oxygen sensors are a more cost-efficient solution.

Dissolved oxygen sensors are relatively inexpensive to purchase and install, and they require minimal maintenance. This means that they can be used in a wide range of applications, from monitoring water quality in small-scale aquariums to large-scale industrial processes.

Additionally, dissolved oxygen sensors can provide real-time data, which can help to optimize processes and reduce costs. For example, in wastewater treatment plants, dissolved oxygen sensors can be used to monitor the effectiveness of the treatment process, allowing operators to adjust the process as needed to ensure that it is operating at maximum efficiency.

Furthermore, dissolved oxygen sensors can be used in remote locations, which can reduce the need for on-site personnel and equipment. This can further reduce costs and improve safety, as it eliminates the need for personnel to work in hazardous environments.

Overall, the cost-effectiveness of dissolved oxygen sensors makes them a valuable tool for a wide range of applications, from scientific research to industrial processes.

Challenges and Limitations of Dissolved Oxygen Sensors

Interference from Other Gases

One of the main challenges in using dissolved oxygen sensors is the potential for interference from other gases present in the environment. These gases can affect the accuracy of the sensor’s readings, leading to inaccurate measurements of dissolved oxygen levels.

Common interfering gases include carbon dioxide (CO2), nitrogen (N2), and methane (CH4), which are all present in the atmosphere and can dissolve in water. Other gases that can interfere with dissolved oxygen sensors include organic compounds, such as alcohols and acids, which can be present in wastewater and other industrial effluents.

Interference from these gases can occur in two ways: direct and indirect. Direct interference occurs when the gas directly affects the sensor’s measurement, while indirect interference occurs when the gas affects the concentration of dissolved oxygen in the water, leading to inaccurate readings.

To mitigate the effects of interference from other gases, it is important to properly calibrate and maintain the dissolved oxygen sensor. This may involve regularly checking the sensor against a reference instrument and adjusting the sensor’s settings to account for any interfering gases present in the environment. Additionally, it may be necessary to use specialized sensors or methods that are designed to reduce or eliminate interference from other gases, such as membrane-based sensors or optical sensors.

Calibration and Maintenance

Proper calibration and maintenance are crucial for the accurate and reliable operation of dissolved oxygen sensors. Calibration ensures that the sensor reads the correct oxygen concentration, while maintenance helps to prevent damage to the sensor and extend its lifespan.

Calibration Frequency

Calibration of dissolved oxygen sensors is typically required at regular intervals, such as every six months or annually, depending on the specific application and usage conditions. Calibration should be performed using a known reference standard, such as a laboratory-prepared calibration solution with a known oxygen concentration.

Calibration Techniques

There are several techniques for calibrating dissolved oxygen sensors, including:

  • Manual Calibration: This involves manually adjusting the sensor’s output to match the reference standard’s oxygen concentration.
  • Automatic Calibration: This uses a built-in calibration routine that automatically adjusts the sensor’s output based on the reference standard’s oxygen concentration.
  • Field Calibration: This technique involves calibrating the sensor in the field using a reference standard solution.

Maintenance

In addition to calibration, regular maintenance is necessary to ensure the continued accurate and reliable operation of dissolved oxygen sensors. Maintenance tasks may include:

  • Cleaning: Regular cleaning of the sensor is necessary to remove any accumulated dirt, debris, or biofilm that can interfere with the sensor’s operation.
  • Replacement: Sensors may need to be replaced periodically, depending on the specific application and usage conditions.
  • Repair: If the sensor is damaged or malfunctioning, it may need to be repaired or replaced.

By following proper calibration and maintenance procedures, dissolved oxygen sensors can provide accurate and reliable measurements for a wide range of applications.

Temperature Effects

Dissolved oxygen sensors are crucial in monitoring the level of oxygen in water bodies. However, temperature effects pose a significant challenge to the accuracy of these sensors. Here are some ways in which temperature affects dissolved oxygen sensors:

  • Increased temperature: Higher temperatures can lead to a decrease in the solubility of oxygen in water. As a result, the concentration of dissolved oxygen decreases, which can lead to false readings by the sensor.
  • Decreased temperature: Lower temperatures can also affect the accuracy of dissolved oxygen sensors. At low temperatures, the oxygen concentration in water increases, leading to higher readings than the actual concentration.
  • Non-linear response: The relationship between temperature and dissolved oxygen concentration is not linear. This means that small changes in temperature can cause significant changes in the sensor’s readings, making it difficult to accurately measure dissolved oxygen levels.
  • Calibration: Dissolved oxygen sensors need to be calibrated to account for temperature effects. However, the calibration process can be complex, and it may not be possible to accurately calibrate the sensor for all temperature ranges.

In conclusion, temperature effects can significantly impact the accuracy of dissolved oxygen sensors. To mitigate these effects, it is important to account for temperature in the sensor’s readings and to regularly calibrate the sensor to ensure accurate measurements.

Future Developments in Dissolved Oxygen Sensor Technology

Miniaturization and Portability

In recent years, there has been a significant push towards miniaturizing dissolved oxygen sensors and making them more portable. This trend is driven by the need for real-time monitoring of dissolved oxygen levels in various applications, including water quality monitoring, environmental research, and biomedical applications.

One of the key benefits of miniaturization is that it allows for the development of smaller, more affordable sensors that can be easily integrated into existing systems or used in remote locations. This makes it possible to monitor dissolved oxygen levels in real-time, which is crucial for many applications, including monitoring water quality in rivers and lakes, assessing the effectiveness of wastewater treatment plants, and monitoring oxygen levels in patients with respiratory disorders.

In addition to miniaturization, portability is also an important aspect of future developments in dissolved oxygen sensor technology. Portable sensors can be easily transported to different locations, allowing for real-time monitoring of dissolved oxygen levels in various environments. This is particularly important in applications such as environmental research, where scientists need to collect data from a variety of locations to better understand the impact of human activities on the environment.

Another benefit of portable dissolved oxygen sensors is that they can be used in remote locations where traditional monitoring methods may be difficult or impossible to implement. For example, in areas with limited access to electricity or where it is difficult to install large monitoring equipment, portable sensors can provide a cost-effective and efficient solution for monitoring dissolved oxygen levels.

Overall, the trend towards miniaturization and portability in dissolved oxygen sensor technology is expected to continue in the coming years, as researchers and industry professionals work to develop sensors that are more affordable, efficient, and accessible. As these sensors become more widely available, they will play an increasingly important role in a variety of applications, from environmental monitoring to medical research.

Advanced Materials and Sensing Techniques

In recent years, significant advancements have been made in the development of dissolved oxygen sensors. These advancements have been made possible by the incorporation of advanced materials and sensing techniques. The use of advanced materials has enabled the creation of sensors that are more accurate, durable, and efficient than their predecessors. Some of the advanced materials used in the development of dissolved oxygen sensors include:

  • Graphene: Graphene is a two-dimensional material with unique electrical and mechanical properties. It has been used in the development of dissolved oxygen sensors due to its high sensitivity and stability. Graphene-based sensors have shown great potential in monitoring dissolved oxygen levels in water bodies, industrial processes, and medical applications.
  • Metal-organic frameworks (MOFs): MOFs are a class of porous materials with a high surface area and tunable pore size. They have been used in the development of dissolved oxygen sensors due to their ability to selectively adsorb oxygen molecules. MOF-based sensors have shown great potential in monitoring dissolved oxygen levels in harsh environments, such as high temperatures and pressures.
  • Carbon nanotubes (CNTs): CNTs are tiny tubes made of carbon atoms that have unique electrical and mechanical properties. They have been used in the development of dissolved oxygen sensors due to their high sensitivity and stability. CNT-based sensors have shown great potential in monitoring dissolved oxygen levels in water bodies, industrial processes, and medical applications.

In addition to the use of advanced materials, sensing techniques have also been developed to improve the performance of dissolved oxygen sensors. One such technique is the use of enzyme electrodes. Enzyme electrodes are sensors that use enzymes to catalyze reactions and generate electrical signals. These sensors have been used in the development of dissolved oxygen sensors due to their high sensitivity and selectivity. Enzyme electrodes have shown great potential in monitoring dissolved oxygen levels in water bodies, industrial processes, and medical applications.

Another sensing technique that has been developed is the use of optoelectronic sensors. Optoelectronic sensors are sensors that use light to detect changes in the environment. These sensors have been used in the development of dissolved oxygen sensors due to their high sensitivity and selectivity. Optoelectronic sensors have shown great potential in monitoring dissolved oxygen levels in water bodies, industrial processes, and medical applications.

Overall, the use of advanced materials and sensing techniques has led to the development of more accurate, durable, and efficient dissolved oxygen sensors. These sensors have great potential in a wide range of applications, including water quality monitoring, industrial process control, and medical diagnosis.

Integration with IoT and AI Systems

Internet of Things (IoT) Integration

As the Internet of Things (IoT) continues to evolve, the integration of dissolved oxygen sensors with IoT networks promises to revolutionize the way we monitor and manage water quality. By connecting these sensors to the internet, real-time data can be transmitted to remote servers, enabling water quality managers to access up-to-date information from anywhere in the world. This can be particularly useful in large-scale water treatment plants, where monitoring dissolved oxygen levels across multiple locations can be challenging.

Artificial Intelligence (AI) Integration

Artificial Intelligence (AI) can be used to analyze the vast amounts of data generated by dissolved oxygen sensors, enabling more accurate predictions of water quality trends. Machine learning algorithms can be trained to identify patterns in the data, such as changes in dissolved oxygen levels caused by variations in weather or water flow. This information can then be used to optimize water treatment processes, improve overall efficiency, and reduce the risk of harmful algal blooms.

Predictive Maintenance

By integrating dissolved oxygen sensors with IoT and AI systems, it is possible to predict when maintenance will be required. This can help to minimize downtime and reduce costs associated with routine maintenance. For example, if a sensor detects a decrease in dissolved oxygen levels, it may indicate a problem with the water treatment process. By analyzing this data with AI algorithms, it may be possible to identify the specific component that requires maintenance, allowing for a more targeted and efficient approach to maintenance.

Remote Calibration

One of the challenges associated with dissolved oxygen sensors is ensuring that they remain calibrated over time. By integrating these sensors with IoT networks, it is possible to perform remote calibration, eliminating the need for on-site technicians to physically check and adjust the sensors. This can save time and reduce costs associated with maintenance.

In conclusion, the integration of dissolved oxygen sensors with IoT and AI systems has the potential to revolutionize the way we monitor and manage water quality. By providing real-time data, enabling more accurate predictions, and facilitating predictive maintenance, these technologies can help to improve efficiency, reduce costs, and minimize the risk of harmful algal blooms.

FAQs

1. What is a dissolved oxygen sensor?

A dissolved oxygen sensor is a device that measures the concentration of oxygen in a liquid or gas. It is commonly used in aquariums, pools, and wastewater treatment plants to monitor the level of dissolved oxygen in the water. The sensor works by measuring the amount of oxygen that is present in the water and converting it into an electrical signal that can be read by a meter or displayed on a digital screen.

2. What is the purpose of a dissolved oxygen sensor?

The primary purpose of a dissolved oxygen sensor is to monitor the level of oxygen in a liquid or gas. This is important because oxygen is essential for the survival of many aquatic organisms, and low levels of dissolved oxygen can be harmful to fish and other aquatic life. By measuring the level of dissolved oxygen, aquarium and pool owners can ensure that their animals are receiving enough oxygen, and wastewater treatment plant operators can monitor the effectiveness of their treatment processes.

3. How does a dissolved oxygen sensor work?

A dissolved oxygen sensor works by measuring the amount of oxygen that is present in the water. The sensor is typically made up of two electrodes, one of which is a reference electrode and the other is a working electrode. The working electrode is coated with a sensitive material that reacts with oxygen, and the amount of current that is generated by this reaction is proportional to the amount of oxygen present in the water. This current is then converted into a voltage signal, which can be read by a meter or displayed on a digital screen.

4. What are some common applications of dissolved oxygen sensors?

Dissolved oxygen sensors are commonly used in aquariums and pools to monitor the level of dissolved oxygen in the water. They are also used in wastewater treatment plants to monitor the effectiveness of the treatment process and to ensure that the water being discharged into the environment meets regulatory standards. Dissolved oxygen sensors are also used in industrial processes, such as in the manufacturing of chemicals and pharmaceuticals, to monitor the level of oxygen in the air or in process streams.

Dissolved Oxygen Measurement: Polarographic vs. Optical DO Sensors

Leave a Reply

Your email address will not be published. Required fields are marked *